Esko Logo Back to Esko Support
Choose your language for a machine translation:


Summary

After upgrading WebCenter and Enterprise to version 22.07 while using a Windows Server OS older than v2019, CADX functionality does not work anymore.

The use of ArtiosCAD Enterprise versions higher than what is provided within the WebCenter ISO on the WebCenter Application server is not supported.


Symptoms

  1. You will find the following error in the Troubleshooting Tools (keep in mind that this can also occur for other errors, this is only one symptom of this issue):

    "java.rmi.ConnectException: Connection refused to host: 127.0.0.1; nested exception is: 
                  java.nat.ConnectException: Connection refused: connect"
  2. Also when attempting to open the Enterprise client on the Application server, you will find the following error:

    " The procedure entry point GetUserDefaultGeoName could not be located in the dynamic link library..."
  3. In the CADX logging, you will find the following error as well:

    "java.lang.Exception: Unable to instantiate CAD-X COM instance (-1)"

Solution

To resolve this issue, you will need to upgrade Windows Server to v2019 or higher.

Workaround

As a workaround, install ArtiosCAD Enterprise version 22.03 (as provided in the WebCenter 22.07 iso) on the Application server.

And then migrate the 22.07 Shared defaults from a client computer.

Article information
Applies to

WebCenter 22.07

ArtiosCAD Enterprise 22.07

Created

 

Last revised

 

AuthorSRAM
Case Number
Contents