Summary

Since version 12.1.1, Plato no longer loads the contents of the placed PDF files to determine which inks are really used. Instead, Plato uses the XMP data to determine the used inks. Since this change, it could happen that the list of inks passed to the Viewer dialog contained not-yet existing inks (when file was not completely loaded yet).

This hotfix also solves the following two issues:

  • Unwanted separations were created because of the “opacity mask only” inks (SmartMark sets were applied incorrectly).
  • Wrong output of opacity masks without any apparent warning or error.

Symptoms

  • Plato could crash when replacing/assigning graphics while the Viewer dialog was open. This results in "System error 5" when replacing station in Plato12.1.1.
  • Unwanted separations were created because of the “opacity mask only” inks (SmartMark sets were applied incorrectly).
  • Wrong output of opacity masks without any apparent warning or error.

More Information

For installation instructions and to download the hotfix, go to https://mysoftware.esko.com/Hotfixes/Details/1204034/12.1.1. 